Towed array vibrations
The customer
- Size: Small - medium enterprise
- Sector: Offshore prospection sector
- Country: United Kingdom
The Problem
- Unknown vibration for different towing conditions
- Fluid induced vibration optimisation required
- Vibration effect on prospection equipment stability unknown
The Project
- Size: 80-100 man-hours
- Duration: 2-3 weeks
Proposed solution
- Evaluation of expected and extreme towing conditions
- Obtain low frequencies incident on the structure
- Fluid induced vibration influence on towing stability assessment
The simulations
- Fluid and turbulence analyses (RANS and DES) to determine induced vibrations (CFD analysis)
- Optimization of the design to improve towing stability (CFD analysis)
Project overal results
- Low frequency vibration amplitude reduction of 75% leading to a notable reduction in prospection equipment signal noise and stability improvement.
- Savings over £23,000 for the customer in prototyping and testing (estimate).
- Savings of more than 14 weeks in development time (estimate).