In-line chemicals dosing
The customer
- Size: Medium-large enterprise
- Sector: Industrial water treatment
- Country: United Kingdom
The Project
- Size: 70-80 man-hours
- Duration: 2-3 weeks
The Problem
- Inefficient additives mixing in the water stream
- Competitive reactions on the pipeline between the chemicals
- Performance of different static mixers unknown (pressure drop and mixing efficiency)
Proposed solution
- Model fluid flow for different static mixers and injector configurations
- Measure the Coefficient of Variation (CoV) for different pipeline locations
The simulations
- Steady state CFD simulation with species tracking for the injection process (CFD analysis)
- Computation of the Coefficient of Variation (CoV) (CFD analysis)
Project overall results
- Definition of the best injector/static mixer configuration. Mixing and pressure drop optimised.
- Savings over £11,000 for the customer in prototyping and testing (estimate).
- Savings of more than 5 weeks in development time (estimate).
For more details about chemicals dosing simulation, please read our CFD analysis of chemical dosing white paper.