Riser analysis
The customer
- Size: Medium-large enterprise
- Sector: Oil and gas
- Country: United Kingdom
The project
- Size: 65-80 man-hours
- Duration: 2-3 weeks
The problem
- Fatigue issues expected on the riser joints
- Early failure of the riser due to fatigue
- Fatigue useful life unknown
Proposed solution
- Fluid dynamic analysis to determine vortex shedding dynamics
- Signal processing to obtain main vortex shedding frequencies
- Determine structure's natural frequencies using a modal analysis
The simulations
- LES model to determine vortex shedding for various current velocities (CFD analysis)
- Fourier transformation for frequency signal processing
- Modal analysis to determine riser structure's natural frequencies (FEA analysis)
Project overall results
- Structure was optimised to avoid VIV frequency range.
- Savings over £38,000 for the customer in prototyping and testing (estimate).
- Savings of more than 8 weeks in development time (estimate).
For more details about VIV calculations, please read our vortex induced vibration on risers and flowlines white paper.